POLYCOAT POLYEURO® 5502F
PRODUCTS (POLYEURO® 5510)
A Division of American Polymers Corp. Two Component Aromatic
Polyurea Protective Coating
DESCRIPTION TECHNICAL DATA
Polyeuro® 5502F is a fast set, rapid curing, 100% solids, Mix Ratio by Volume .......................................... 1A : 1B
flexible, aromatic, two component spray polyurea that can be Pot Life ............................................................... 2-4 seconds
applied to suitably prepared concrete and metal surfaces. Its Tack Free Time ................................................... 15-20 secs
extremely fast gel time makes it suitable for applications Recoat Time ........................................................ 0-6 hours
down to -20°F. It may be applied in single or multiple Viscosity at 150-160°F (66.5-71°C), Brookfield:
applications without appreciable sagging and is relatively Part-A ................................................................. 50 ± 20 cps
insensitive to moisture and temperature allowing application Part-B ................................................................. 50 ± 20 cps
in most temperatures. Density (Side A & B Combined) ........................ 8.75 lbs/gal
Flash Point .......................................................... >200°F
FEATURES Hardness, ASTM D-2240 .................................. 50 ± 5 D
Tensile, ASTM D-412* ........................................ 2800 ± 300 psi
ï¶Zero VOC (100% Solids) ï¶ Seamless Elongation, ASTM D-412* .................................. 375% ± 50%
Tear, ASTM D-412* ............................................ 450 ± 50 pli
ï¶Excellent Thermal Stability ï¶ Odorless Service Temperature ......................................... -40°F to 250°F
Water Vapor Permeability ASTM E-96 .............. 0.00042
ï¶No Toxic Vapors ï¶Non-Reactive
(*These physical properties from sample sprayed with EXP-2 @ 2000
ï¶Meets USDA Criteria psi minimum, with Gusmer GX7-400 mechanical purge gun @ 150-
160°F. Different machine and parameter will change these
ï¶Low Temperature Flexibility properties. User should perform their own independent testing as
properties are approximate.)
ï¶Good Chemical Resistance
ï¶Coats Carbon or Mild Steel Metals without Primer
ï¶Installed With or Without Reinforcement in Transitional
Areas
TYPICAL USES SURFACE PREPARATION
In general, coating performance and adhesion are directly
ï¶Airports ï¶Power Plants proportional to surface preparation. Most failures in the
performance of surface coatings can be attributed to poor
ï¶Refineries ï¶Structural Steel surface preparation. Polyurea coatings rely on the structural
strength of the substrate to which they are applied. All sur-
ï¶Fertilizer Plants ï¶Warehouse Floors faces must be free of dust, dirt, oil, grease, rust, corrosion and
other contaminants. When coating substrates previously
ï¶Mining Operations ï¶Cold Storage Facilities used, it is important to consider the possibility of substrate
absorption, which may affect the adhesion of the coating
ï¶Food Processing Plants ï¶Landfill Containment system, regardless of the surface preparation. Polycoat
recognizes the potential for unique substrates from one
ï¶Marine Environments ï¶Paper and Pulp Mills project to another. The following information is for general
reference, and for project-specific questions, contact Polycoat.
ï¶Secondary Containment ï¶Parking Garage Decks New and Old Concrete:
Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5. New
ï¶Walkways and Balconies concrete must be cured for 28 days prior to product applica-
tion. Surface must be clean, dry, sound and offer sufficient
ï¶Water and Waste Water Treatment rofile for product adhesion. Remove all dust, dirt, oil, form release
agents, curing compounds, salts, efflorescence, laitance and other
ï¶Industrial and Manufacturing Facilities foreign matter by shotblasting and/or suitable chemical means, in
accordance with local chemical regulations. Rinse thoroughly, to
COLORS achieve a pH between 8.0 and 11.0. Allow to dry completely. If old
Neutral. Custom colors are available upon request. concrete has a surface that has deteriorated to an unacceptably
rough surface, Polycoat Products PC-260 or a mixture of Polyprime
Due to its aromatic composition, Polyeuro® 5502F will tend 21 and sand should be used as a repair agent for cracks, spalls, bug
to yellow or darken in color and will become flat after expo- holes and voids. Upon full cure of the repair agent, prime the entire
sure to UV light. Polyeuro® 5502F may be topcoated with surface intended for coating.
an aliphatic polyurethane/polyurea coating for a colorfast Concrete Surface Preparation Reference:
finish. ASTM D4258 - Standard practice for cleaning concrete
ASTM D4259 - Standard practice for abrading concrete
PACKAGING ASTM D4260 - Standard practice for etching concrete
10 gallon kit: One 5 gallon pail of Part-A and one 5 gallon pail ASTM F1869 - Standard test method for measuring moisture vapor
of Part-B. emission rate of concrete ICRI 03732 - Concrete surface preparation.
100 gallon kit: One 50 gallon drum of Part-A and one 50 gallon
drum of Part-B.
COVERAGE
Polyeuro® 5502F may be applied at any rate to achieve
desired thickness. Theoretical coverage for 1 mil thickness
is one gallon per 1600 sq. ft.
14722 Spring Avenue  Santa Fe Springs, CA 90670-5108 USA  Tel: 562/802-8834  Fax: 562/921-7363  www.polycoatusa.com  Copyright  August 2011 Polycoat Products