Page 6 - Industrial Coatings
P. 6

POLYCOAT                                             POLYEURO® 5502F
                    PRODUCTS                                             (POLYEURO® 5510)

                    A Division of American Polymers Corp.           Two Component Aromatic
                                                                  Polyurea Protective Coating

DESCRIPTION                                                       TECHNICAL DATA
Polyeuro® 5502F is a fast set, rapid curing, 100% solids,         Mix Ratio by Volume .......................................... 1A : 1B
flexible, aromatic, two component spray polyurea that can be      Pot Life ............................................................... 2-4 seconds
applied to suitably prepared concrete and metal surfaces. Its     Tack Free Time ................................................... 15-20 secs
extremely fast gel time makes it suitable for applications        Recoat Time ........................................................ 0-6 hours
down to -20°F. It may be applied in single or multiple            Viscosity at 150-160°F (66.5-71°C), Brookfield:
applications without appreciable sagging and is relatively        Part-A ................................................................. 50 ± 20 cps
insensitive to moisture and temperature allowing application      Part-B ................................................................. 50 ± 20 cps
in most temperatures.                                             Density (Side A & B Combined) ........................ 8.75 lbs/gal
                                                                  Flash Point .......................................................... >200°F
FEATURES                                                          Hardness, ASTM D-2240 .................................. 50 ± 5 D
                                                                  Tensile, ASTM D-412* ........................................ 2800 ± 300 psi
Zero VOC (100% Solids)        Seamless                          Elongation, ASTM D-412* .................................. 375% ± 50%
                                                                  Tear, ASTM D-412* ............................................ 450 ± 50 pli
Excellent Thermal Stability   Odorless                          Service Temperature ......................................... -40°F to 250°F
                                                                  Water Vapor Permeability ASTM E-96 .............. 0.00042
No Toxic Vapors              Non-Reactive
                                                                  (*These physical properties from sample sprayed with EXP-2 @ 2000
Meets USDA Criteria                                              psi minimum, with Gusmer GX7-400 mechanical purge gun @ 150-
                                                                  160°F. Different machine and parameter will change these
Low Temperature Flexibility                                      properties. User should perform their own independent testing as
                                                                  properties are approximate.)
Good Chemical Resistance

Coats Carbon or Mild Steel Metals without Primer

Installed With or Without Reinforcement in Transitional

Areas

TYPICAL USES                                                      SURFACE PREPARATION
                                                                  In general, coating performance and adhesion are directly
Airports                     Power Plants                       proportional to surface preparation. Most failures in the
                                                                  performance of surface coatings can be attributed to poor
Refineries                   Structural Steel                   surface preparation. Polyurea coatings rely on the structural
                                                                  strength of the substrate to which they are applied. All sur-
Fertilizer Plants            Warehouse Floors                   faces must be free of dust, dirt, oil, grease, rust, corrosion and
                                                                  other contaminants. When coating substrates previously
Mining Operations            Cold Storage Facilities            used, it is important to consider the possibility of substrate
                                                                  absorption, which may affect the adhesion of the coating
Food Processing Plants       Landfill Containment               system, regardless of the surface preparation. Polycoat
                                                                  recognizes the potential for unique substrates from one
Marine Environments          Paper and Pulp Mills               project to another. The following information is for general
                                                                  reference, and for project-specific questions, contact Polycoat.
Secondary Containment        Parking Garage Decks               New and Old Concrete:
                                                                  Refer to SSPC-SP13/NACE 6, or ICRI 03732: CSP 3-5. New
Walkways and Balconies                                           concrete must be cured for 28 days prior to product applica-
                                                                  tion. Surface must be clean, dry, sound and offer sufficient
Water and Waste Water Treatment                                  rofile for product adhesion. Remove all dust, dirt, oil, form release
                                                                  agents, curing compounds, salts, efflorescence, laitance and other
Industrial and Manufacturing Facilities                          foreign matter by shotblasting and/or suitable chemical means, in
                                                                  accordance with local chemical regulations. Rinse thoroughly, to
COLORS                                                            achieve a pH between 8.0 and 11.0. Allow to dry completely. If old
Neutral. Custom colors are available upon request.                concrete has a surface that has deteriorated to an unacceptably
                                                                  rough surface, Polycoat Products PC-260 or a mixture of Polyprime
Due to its aromatic composition, Polyeuro® 5502F will tend        21 and sand should be used as a repair agent for cracks, spalls, bug
to yellow or darken in color and will become flat after expo-     holes and voids. Upon full cure of the repair agent, prime the entire
sure to UV light. Polyeuro® 5502F may be topcoated with           surface intended for coating.
an aliphatic polyurethane/polyurea coating for a colorfast        Concrete Surface Preparation Reference:
finish.                                                           ASTM D4258 - Standard practice for cleaning concrete
                                                                  ASTM D4259 - Standard practice for abrading concrete
PACKAGING                                                         ASTM D4260 - Standard practice for etching concrete
10 gallon kit: One 5 gallon pail of Part-A and one 5 gallon pail  ASTM F1869 - Standard test method for measuring moisture vapor
of Part-B.                                                        emission rate of concrete ICRI 03732 - Concrete surface preparation.

100 gallon kit: One 50 gallon drum of Part-A and one 50 gallon
drum of Part-B.

COVERAGE
Polyeuro® 5502F may be applied at any rate to achieve
desired thickness. Theoretical coverage for 1 mil thickness
is one gallon per 1600 sq. ft.

14722 Spring Avenue  Santa Fe Springs, CA 90670-5108 USA  Tel: 562/802-8834  Fax: 562/921-7363  www.polycoatusa.com  Copyright  August 2011 Polycoat Products
   1   2   3   4   5   6   7   8   9   10   11